Thứ Ba, 27 tháng 12, 2016

Phụ kiện van công nghiệp, hãng Gestra, model: BAE 46 / BA 46, MPA 46 / PA 46

Liên hệ mua hàngLại Lê Anh Kiệt
SĐT: 097 529 1433
Nhà phân phối chính thức tại Việt Nam chuyên cung cấp thiết bị trong các lĩnh vực tự động hóa

BAE 46 / BA 46BAE 46 / BA 46

Desalting valve

Special designs for specific tasks, i.e. low-noise and low-wear level relaxation.
BA(E) 46PN 40DN 15-50C 22.8
BA(E) 47PN 63DN 15-50C 22.8
BA(E) 210PN 250DN 25C 22.8
BA(E) 211PN 320DN 2513 CrMo 4 4
ZK(E) 29PN 160DN 5013 CrMo 4 4
MPA 46 / PA 46MPA 46 / PA 46

Blow-down valve

The GESTRA security concept, i.e. boiler and spring pressure ensures a safe close and the downstream radial level nozzle for low-wear operation.
(M)PA 46PN 40DN 20-50C 22.8
(M)PA 47PN 63DN 25, 40, 50C 22.8
(M)PA 110PN 250DN 2513 CrMo 4 4

Surveillance on contamination inleakage

In closed loops (emergency power generators, etc.)
Surveillance
ORGS 11-2, PN 6, C 22.8
In open circuits and condensate systems
Surveillance
There is a risk of inleakage by oils, grease, etc.:
OR 52-5, PN 10, G 3/8, GG
OR 52-6, PN 10, G 3/8, 1.4580
There is a risk of inleakage by acids, alkalis, etc.:
Electrode LRG 12-1, PN 10, G 11/4
Transmitter LRT 1-6b
Limit switch URS 2

GESTRA systems engineering

PWT-XPSPWT-XPS

Heat transfer system type PWT-XPS

The GESTRA heat transfer system consisting of a plate heat exchanger XPS in fully welded version in the shell-&-plate design and is equipped with the following components: on the steam side with blocking valve, strainer and electric control valve with safety reset and on the condenser side with pumping condensate drain, check valve, blocking valve.
Measuring and control technology consists of: Safety temperature limiter, safety pressure limiter, temperature sensor, thermostat, thermometer, manometer and safety valve. The system is ready for connection mounted and wired and is delivered on a stable base frame.
SDLSDL

Condensate tank type SDL

Cylindrical condensate collecting tanks are designed as standard version for condensate flow rates up to 30 t / h and an operating pressure of 4 bar Max. Higher pressures and pressure sets are available on request. There are containers in lying and standing versions. They are equipped with two adjacent condensate pumps, bimetallic dial thermometer, valve submersible indicator, GESTRA level controller and level electrodes for automatic operation of pumps, check valves, safety valve, anti-vacuum valve, vents, shut-off devices, high pressure centrifugal pumps, manometer and control cabinet to the pump control assembled ready for connection.
Steam converters, pure steam generatorSteam converters, pure steam generator

Steam converters, pure steam generator

Steam converters produce saturated steam for a secondary system of steam from steam or hot water. Steam generators used mainly for the production of pure steam, where no harmful substances, such as hydrazine, may be included. Applications are e.g. for sterilizing equipment in hospitals, for steam and dry chambers in the food processing, for steam heating systems, for the production of distillates etc. Pure steam systems are available with mechanical, electrical or electro-pneumatic heating steam control.